ISO/IEC 17025 Accredited Calibration Laboratory

Laboratory for calibration Reg. No 14-LK has confirmed the accreditation of BSA with Order № A 329/15.08.2019 (BDS EN ISO/ IEC 17025: 2018).

Accredited laboratory for calibration of measuring instruments to Microsyst Reg. No 14-LK has confirmed the accreditation of BSA with Order № A 81 / 12.03.2018 (EN ISO / IEC 17025: 2018) to perform calibration of:

  • Thermometers – digital, analog and liquid (from minus 45 C to 650C);
  • Resistors (RTD) and Termocouple for temperature (from minus 45 C to 650 C);
  • Hygrometer for relative humidity of the air (from 10% to 90% rh);
  • Gauges, measuring devices and setting the vacuum pressure (from vacuum to 400 bar);
  • Secondary converters with input electric signal (DCU, DCI and R) indicating temperature, relative humidity, pressure;
  • Secondary converters with input electric signal and unified output electric signal;
  • Calibrators with output electric signal (DCU, DCI and R) for simulating of non-electrical quantities;
  • Voltmeters for DC (to 750V);
  • Voltmeters for AC (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
  • Calibrators for DC voltage (to 750V);
  • Calibrators for AC voltage (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
  • Ammeters for DC (to 2A);
  • Ammetrs for AC (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
  • Calibrators for DC current (to 2A)
  • Calibrators for AC current (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
  • Ohmeters (to 100MΩ)
  • Resistors and Resistance decade ;
  • Voltmeters for DC (to 750V);
  • Voltmeters for AC (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
  • Calibrators for DC voltage (to 750V);
  • Calibrators for AC voltage (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
  • Ammeters for DC (to 2A);
  • Ammetrs for AC (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
  • Calibrators for DC current (to 2A)
  • Calibrators for AC current (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
  • Ohmeters (to 100MΩ)
  • Resistors and Resistance decade ;
  • Thermometers – digital, analog and liquid (from minus 45 C to 650C);
  • Resistors (RTD) for temperature (from minus 45 C to 650 C);
  • Termocouple for temperature (from minus 45 C to 650 C);

Microsyst Calibration Laboratory can do calibration for pressure quipment as follows:

  • Hygrometer for relative humidity of the air (from 10 to 90% rh);

Microsyst Calibration Laboratory can do calibration for pressure quipment as follows:

  • Gauges, measuring devices and setting the vacuum pressure (from vacuum to 400 bar)

Microsyst calibration laboratory can calibrate also:

  • Secondary converters / indicators/with input electric signal (DCU, DCI and R) indicating temperature, relative humidity, pressure;
  • Secondary converters /transmitters/with input electric signal and unified output electric signal;
  • Calibrators with output electric signal (DCU, DCI and R) for simulating non-electrical quantities;