Laboratory for calibration Reg. No 14-LK has confirmed the accreditation of BSA with Order № A 329/15.08.2019 (BDS EN ISO/ IEC 17025: 2018).
Accredited laboratory for calibration of measuring instruments to Microsyst Reg. No 14-LK has confirmed the accreditation of BSA with Order № A 81 / 12.03.2018 (EN ISO / IEC 17025: 2018) to perform calibration of:
- Thermometers – digital, analog and liquid (from minus 45 C to 650C);
- Resistors (RTD) and Termocouple for temperature (from minus 45 C to 650 C);
- Hygrometer for relative humidity of the air (from 10% to 90% rh);
- Gauges, measuring devices and setting the vacuum pressure (from vacuum to 400 bar);
- Secondary converters with input electric signal (DCU, DCI and R) indicating temperature, relative humidity, pressure;
- Secondary converters with input electric signal and unified output electric signal;
- Calibrators with output electric signal (DCU, DCI and R) for simulating of non-electrical quantities;
- Voltmeters for DC (to 750V);
- Voltmeters for AC (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
- Calibrators for DC voltage (to 750V);
- Calibrators for AC voltage (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
- Ammeters for DC (to 2A);
- Ammetrs for AC (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
- Calibrators for DC current (to 2A)
- Calibrators for AC current (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
- Ohmeters (to 100MΩ)
- Resistors and Resistance decade ;
- Voltmeters for DC (to 750V);
- Voltmeters for AC (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
- Calibrators for DC voltage (to 750V);
- Calibrators for AC voltage (to 750V, frequency 45 – 65 Hz; frequency 1 kHz);
- Ammeters for DC (to 2A);
- Ammetrs for AC (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
- Calibrators for DC current (to 2A)
- Calibrators for AC current (to 2A, frequency 45 – 65 Hz; frequency 1 kHz);
- Ohmeters (to 100MΩ)
- Resistors and Resistance decade ;
- Thermometers – digital, analog and liquid (from minus 45 C to 650C);
- Resistors (RTD) for temperature (from minus 45 C to 650 C);
- Termocouple for temperature (from minus 45 C to 650 C);
Microsyst Calibration Laboratory can do calibration for pressure quipment as follows:
- Hygrometer for relative humidity of the air (from 10 to 90% rh);
Microsyst Calibration Laboratory can do calibration for pressure quipment as follows:
- Gauges, measuring devices and setting the vacuum pressure (from vacuum to 400 bar)
Microsyst calibration laboratory can calibrate also:
- Secondary converters / indicators/with input electric signal (DCU, DCI and R) indicating temperature, relative humidity, pressure;
- Secondary converters /transmitters/with input electric signal and unified output electric signal;
- Calibrators with output electric signal (DCU, DCI and R) for simulating non-electrical quantities;